GPB300D
0Vol%
Type: L30A
| Electrical power | 34.30 MWe |
| Fuel consumption | 85.10 MWe |
| Electrical efficiency | 40.3 % |
| Exhaust gas mass flow | 92.0 kg/s |
| Exhaust gas temperature | 502 °C |
| Generator voltage | 10.5 kV |
| Saturated steam output at 8 bar(g) | 55.0 t/h |
| Emissions |
NOx: 15 ppm (9 ppm) CO2: 25 ppm |
Performance under ISO conditions w/o duckt losses at Generator Terminal.
GPB300D-H2
0 – 30Vol%
Type: L30A
| Electrical power | 33.70 MWe |
| Fuel consumption | 83.02 MWe |
| Electrical efficiency | 40.6 % |
| Exhaust gas mass flow | 88.7 kg/s |
| Exhaust gas temperature | 511 °C |
| Generator voltage | 10.5 kV |
| Saturated steam output at 8 bar(g) | 55.0 t/h |
| NOx reduction process | DLE |
| Emissions |
NOx: 25 ppm CO2: 25 ppm |
Performance at 15°C, 60% RH, at Generator Terminal, Inlet Pressure Loss 0.0 kPa, Exhaust Pressure Loss 0.0 kPa. Performance data valid for: 30% H2 / 70% Natural Gas.

Hydrogen Technology for Gas Turbines
DLE for natural gas
| Burner configuration: | DLE for natural gas |
| NOx-reduction: | „Dry" |
| H2-content: | 0 – 30 Vol% |
GPB300-H2
0 – 100Vol%
Type: L30A
| Electrical power | 34.12 MWe |
| Fuel consumption | 86.12 MWe |
| Electrical efficiency | 39.6 % |
| Exhaust gas mass flow | 90.5 kg/s |
| Exhaust gas temperature | 436 °C |
| Generator voltage | 10.5 kV |
| Saturated steam output at 8 bar(g) | 55.0 t/h |
| NOx reduction process | Water injection |
| Emissions |
NOx: on request CO2: 0.0 % |
Performance at 15°C, 60% RH, at Generator Terminal, Inlet Pressure Loss 0.0 kPa, Exhaust Pressure Loss 0.0 kPa. Performance data valid for: 100% H2.

Hydrogen Technology for Gas Turbines
Diffusion flame
| Burner configuration: | Diffusion flame |
| NOx-reduction: | „Dry“ water/steam |
| H2-content: | 0 – 100 Vol% |